+91-9811151459, 8586999563    Follow us on : |

Eaton 9PX 1000W RT2U (tower/rack 2U)

31000 Rs. 30070

You Save : Rs. 930 (3%)
Product Code
9PX1000IRT2U
Quick Overview

Eaton 9PX 1000W RT2U (tower/rack 2U)

9PX1000IRT2U

Eaton 9PX 1000W RT2U (tower/rack 2U)

 

 
General
Topology On-line double conversion with Power Factor Correction (PFC) system
Configuration Rack/Tower
Part Number 9PX1000IRT2U
Rating (VA/Watts) 1000/1000
Dimensions (H x W x D, mm) 86.5 x 440 x 450
Weight (kg) 17.4
Warranty 3 years electronics, 2 years battery
Rail Kit Included Yes
 
Electrical Input
Connection

(1) IEC-320-C14

IEC C14
Input Voltage Range 176-276V without derating (up to 100-276V with derating)
Nominal Voltage 200/208/220/230/240V
Frequency 50/60 Hz autoselection
Frequency Range 40-70 Hz
 
Electrical Output
Nominal Voltage 200/208/220/230/240V
Output Receptacles

(8) IEC-320-C13

IEC C13
Efficiency (Normal Mode) Up to 91.5% in online mode (up to 97.5% in Hi-efficiency mode)
Output Frequency 50/60 Hz autoselect, frequency converter mode
 
Battery

Runtime
(Minutes)

 

200

400

600

800

1000

0

500

1000

1500

2000

2500

3000

3500

 

 

Standard Runtime

 

With 1 EBM

 

With 2 EBM

 

With 3 EBM

 

With 4 EBM

Load (Watts)

Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc. Actual runtime may vary from +/- 15% around these typical values

Show:
Standard Runtime
  With 1 EBM
  With 2 EBM
  With 3 EBM
  With 4 EBM

Hover over graph for detailed runtime values

 

Battery Management ABM® & Temperature compensated charging method (user selectable), Automatic battery test, deep discharge protection, automatic recognition of external battery units
Extended Battery Capability EBM (2U)
 
Communications
User Interface Multilingual graphical LCD display
Communication Ports 1 USB port + 1 serial RS232 port + 1 mini-terminal block for remote ON/OFF + 1 mini-terminal block for Remote Power Off + 1 mini-terminal block for Output relay
Communication Slot 1 slot for Network-MS card, ModBus-MS or Relay-MS cards.
 
Environmental & Standards
Audible Noise 35dB
Operating Temperature 0 to 40°C
Safety markings IEC/EN 62040-1, UL 1778, CSA 22.2
EMC Markings IEC/EN 62040 -2 , FCC Class B, CISPR22 Class B
Approvals CE /CB report (TUV) / cULus / EAC / RCM / KC / Energy Star
 
 
   

 

 

In the interests of continuous product improvement all specifications are subject to change without notice.

Customer review

Leave your reviw

Video

Loading...